Most enquiries we receive start in the same place: a number of valves and a size. Twenty-four DN150 valves. It’s a reasonable starting point, and it’s usually the part of the system a grower can picture most clearly.
But valves are one layer of a smart irrigation system, not the system. The pump still has to start and stop. The valves still have to reach the internet somehow. There are things that have to be bolted on before a valve can be installed at all. And what each of those layers should be, on your farm specifically, is determined by facts about the site rather than by anything in a catalogue.
This guide is the framework we use to turn a farm’s actual conditions into a complete equipment specification — the five layers of a system, what governs each one, and a worked example on a real 250-hectare project.
In this guide:
→ The five layers of a complete system
→ What your farm decides about each layer
The Five Layers of a Complete System
Working from the water source outward, every automated irrigation system has the same anatomy. Leave a layer out and the system either doesn’t run or doesn’t get installed.
1. Pump control — the head of the system
If the valves are automated but the pump isn’t, someone still has to start the pump. Remote pump control is what closes that gap, so the pump runs when irrigation runs and stops when it finishes. It’s also the layer most often missing from an equipment list, because it sits at the pump house rather than in the field.
2. Communication — how the field reaches you
Two architectures. With 4G, every valve carries its own SIM card and connects independently. With LoRaWAN, the valves talk to a gateway and only the gateway needs internet. This isn’t a preference — the valve count and the site layout decide it, and the decision shapes the cost of the system for the next decade.
3. Valves — the layer everyone starts with
The working units. Ball valves for smaller diameters, butterfly valves for larger lines, in PVC, ductile iron or stainless steel depending on the water and the site. Diameter, pressure rating and body material all follow from the pipework rather than from preference.
4. Sensing — optional, and often misunderstood
Three different devices doing three different jobs:
- Pressure sensors monitor line pressure and raise an alarm when it moves outside the expected range — the signature of a burst or a blockage.
- Soil sensors can be linked to the valves: set a moisture threshold, and irrigation starts automatically when the soil drops below it.
- Weather stations collect and display data such as wind direction and humidity. They are monitoring devices — they do not trigger valve action.
A DISTINCTION WORTH MAKING EARLY — Soil sensors can drive automatic irrigation. Weather stations cannot. Both are useful, but they are not interchangeable, and specifications frequently assume they are.
5. Fittings — the layer nobody lists
Butterfly valves install between two flanges. Each valve needs 2 flanges and 4 bolts, and they aren’t part of the valve. On a 24-valve project that’s 48 flanges and 96 bolts — usually sourced locally, but they have to be on somebody’s list or the valves sit in their boxes on installation day.
One related item that is not ours to supply: on a 4G system, the SIM cards are bought locally by the customer, from a local network operator. Worth planning for, because 4G valves don’t communicate without them.
What Your Farm Decides About Each Layer
Here is the part that matters. Each layer above is configured by a specific set of facts about the site — and until those facts are known, no honest specification is possible.

Pump control is decided by what’s already at the pump house
The critical question is whether the pump already has a starter panel — star-delta, soft starter, or VFD.
If it does, remote control can usually be added with a data transfer unit providing a dry-contact relay output, wired to signal the existing panel. The controller never carries motor current, so the pump’s power rating stops being its problem. If there is no starter panel, a complete control cabinet has to be designed and built for that pump’s rating.
Communication is decided by valve count and layout
The threshold is around fifteen valves. Below that, individual 4G is usually simpler. Above it the arithmetic turns: one gateway bought once, versus a monthly subscription on every valve, every year, for the life of the system.
Then the second question — how many gateways — which is where a hectare figure stops being enough. A gateway covers a radius of roughly 1 to 4 km: up to 4 km with clear line of sight, closer to 1 km where terrain, buildings or tall crops get in the way. Two farms of identical area can need different numbers of gateways depending on how the blocks are arranged.
This is why we ask for a site plan rather than just an area. (More on the two architectures: 4G vs LoRaWAN.)
Valves are decided by the pipework
Diameter comes from the pipe, not from preference. Working pressure has to be confirmed against the valve’s rating. Body material follows the water chemistry and the site conditions. Whether the project is a new installation or a retrofit onto existing pipework changes the fittings and the installation method. (Material trade-offs: PVC vs ductile iron vs stainless steel.)
Sensing is decided by the crop and how automatic you want it
Pressure sensors suit long or branched networks where a break is expensive to find by walking. Soil sensors suit growers who want irrigation to respond to conditions rather than only to a clock. Weather stations suit sites where the data is useful to have on record. None of them is mandatory, and specifying all three by default is how budgets get spent on equipment nobody uses.
A Worked Example: 250 Hectares in West Africa
Here is the framework applied to a real project — an engineering contractor sourcing for a 250-hectare farm in West Africa. The starting request was a short list: 24 smart butterfly valves at DN150, control software, a control cabinet, a weather station, soil sensors.
What follows is how that list turned into a system specification. No prices — just the reasoning.
A second worked example, a much smaller one, runs through the same framework from the other end: a one-acre LoRaWAN pilot on a vegetable farm in Kenya.
Communication: LoRaWAN, and two gateways
Twenty-four valves is well above the fifteen-valve threshold, so LoRaWAN was the clear choice — one gateway instead of twenty-four SIM subscriptions running indefinitely.
Then the layout question. The site is one contiguous 250-hectare block, which sounds like a single gateway would do. But against a realistic coverage radius, and with the valves distributed across the full area, two gateways is the right specification for reliable coverage — a conclusion that only became clear from the site plan, not from the area figure.
The gateway also has to reach the internet, by one of two routes: a SIM card in the gateway itself (requiring 4G coverage at the farm), or an ethernet cable from a router at the farm office — including a satellite router. On a remote site, confirming which of those exists is not a detail.

Pump control: one question first
The pump turned out to be 185 kW — substantial. And this is exactly where the earlier question decides everything: if that pump already has a starter panel, a DTU with dry-contact output integrates with it for remote start and stop. If it doesn’t, a complete cabinet at that rating has to be built.
Before proposing either, the details that matter: pump type (submersible, vertical turbine, horizontal centrifugal), rated voltage and frequency, full-load current, three-phase confirmation, rated flow and head, and whether the site runs on grid power or a generator. A photograph of the pump nameplate answers most of it at once.
Valves: confirming the pressure
Twenty-four DN150 butterfly valves, PVC bodies, all LoRaWAN versions. One point needed settling before anything else: our valves are rated to a maximum working pressure of 10 bar, so the pipeline’s operating pressure had to be confirmed against that figure.
In practice this rarely turns into an obstacle — 10 bar comfortably covers what field irrigation runs at, and it did here. But it’s a check worth making explicitly rather than assuming, because it’s the one specification that determines whether the valve is suitable at all.
Sensing and software
The weather station was specified for monitoring, and that’s what it does — it collects and displays data, and does not act on the valves. The soil sensors are available in a LoRaWAN version with a DTU and can be linked to the valves, so irrigation starts automatically below a set moisture threshold. The control platform is our own, and it’s free — no subscription, no licence fee — which meant one line on the original list needed no quotation at all.

And the fittings
Twenty-four butterfly valves means 48 flanges and 96 bolts, none of which appeared on the original list. They can be sourced locally or shipped with the order, but either way they had to be specified — a set of valves without flanges cannot be installed.
The Information to Gather First
If you’re planning a system — with us or anyone else — these are the facts that make a real specification possible. Gathering them before you ask will save several rounds of correspondence.
The site
- Total area, and whether it’s one block or separate locations
- A layout drawing or map, showing roughly where the valves will sit
- Country and region — this determines the LoRaWAN frequency band
- Is there 4G coverage at the site? Is there a router, satellite or otherwise?
The water and pipework
- Pipe diameter at each point a valve will be installed
- Working pressure of the pipeline
- Pipe material — PVC, HDPE or steel
- New installation, or a retrofit onto existing pipework?
- Anything notable about the water — saline, high mineral content, fertigation
The pump
- Power rating and phase — or simply a photo of the nameplate
- Does it already have a starter panel? Star-delta, soft starter or VFD
- Pump type: submersible, vertical turbine, horizontal centrifugal
- Grid power or generator, and whether supply is stable
The farming
- Crop, and the irrigation method — drip, sprinkler or otherwise
- How many zones you want to control independently
- Whether you want irrigation to respond to soil conditions, or run to a schedule
Frequently Asked Questions
What does a complete smart irrigation system include besides the valves?
Five layers, of which valves are only one. At the head of the system there is pump control, so the pump starts and stops with the irrigation rather than separately. Then the communication layer — either 4G in each valve or a LoRaWAN gateway serving all of them. Then the valves themselves. Then optional sensing: pressure sensors for alarms, soil sensors that can trigger irrigation automatically, and weather stations for monitoring. Finally the fittings, which for butterfly valves means two flanges and four bolts per valve.
How many valves before LoRaWAN is cheaper than 4G?
Around fifteen. Below that, giving each valve its own 4G SIM is usually simpler. Above roughly fifteen valves the arithmetic turns: you buy one gateway once, instead of paying a monthly subscription on every valve, every year, for the life of the system. On a site with twenty-four valves the LoRaWAN route is clearly more economical, and it also removes the job of sourcing and managing that many SIM cards.
How many LoRaWAN gateways does a large farm need?
It depends on layout, not just area. A gateway covers a radius of roughly 1 to 4 km — up to 4 km with clear line of sight, and about 1 km where terrain, buildings or tall crops interrupt it. That is why a site plan matters more than a hectare figure: two farms of the same size can need different numbers of gateways depending on how the blocks are arranged and what stands between them.
Does a smart irrigation system need a new pump control panel?
Often not. If the pump already has a starter panel — star-delta, soft starter or VFD — remote control can usually be added with a data transfer unit providing a dry-contact relay output, which signals the existing panel to start and stop. A complete new control cabinet is only needed where no starter exists. The difference between those two answers is substantial, which is why it is one of the first things worth establishing.
Can soil sensors start irrigation automatically?
Yes. Soil sensors can be linked to valves so that irrigation starts when moisture falls below a threshold you set. Weather stations work differently — they collect and display data such as wind direction and humidity, but they do not trigger any valve action. It is worth being clear about that distinction when specifying a system, because the two devices are often assumed to do the same job.
Planning a system for your own site?
The layers, in detail:
>>> Remote Pump Control · LoRaWAN Gateway · Butterfly Valves · Pressure Sensors
Related reading:
>>> 4G vs LoRaWAN · Choosing a valve body material · Evaluating suppliers at scale · How a smart farm is structured · See the five layers working together · The Complete Guide to Smart Irrigation Valves
Send us what you have.
>>> Share your site plan, pipe sizes and pump details, or tap the WhatsApp button in the corner of any page. We’ll work through the layers with you and put together a specification matched to your farm — including telling you which items you should source elsewhere.
AriValve builds solar-powered, motorized wireless smart irrigation valves and the platform that runs them, deployed across 30+ countries. The worked example above is drawn from a real project, with identifying details removed.