Most people approaching remote pump control for the first time get stuck on the same worry: “I don’t even know enough about my pump yet — how am I supposed to choose the right controller?”
It’s a fair concern, and the good news is that the choice is much simpler than it appears. You don’t need any electrical training, and you don’t need your pump fully decided. Everything hinges on a single figure — your pump’s rated power. Once you know that, the right configuration falls into place on its own.
Below, we’ll show you that one figure, then walk through the three controller configurations and exactly what’s inside each cabinet — so you can match your own pump and see precisely what you’d be getting. We’ll finish with the question nearly everyone asks in the end: do you need a variable frequency drive (VFD), or not?
In this guide:
→ Start with one number: your pump’s rated power
→ The three configurations, matched to pump power
→ Do you actually need a VFD? Required vs optional
→ How it works: phone to pump in three steps
Start With One Number: Your Pump’s Rated Power
Before anything else, find your pump’s rated power. It’s printed on the nameplate — the metal or sticker label on the motor — usually in kilowatts (kW), horsepower (HP), or both. This one figure is what a remote pump control is built around.
A quick clarification that saves a lot of confusion: rated power is not the same as how much power the pump draws while running. The rated value on the nameplate is the number you want. It decides which main breaker is used, which core component drives the motor, and how big the cabinet ends up being.
If your nameplate uses HP and you think in kW (or the reverse), the math is easy: 1 HP is about 0.75 kW, so a 10 HP pump is roughly 7.5 kW. Throughout this guide we lead with kW and put approximate HP in brackets.
GOOD NEWS — You don’t need the pump finalized to start. Controllers are matched to power ranges, not exact models — so a rough idea (“somewhere around 1–3 kW”) is already enough to plan.
The Three Configurations, Matched to Pump Power
However big your pump is, the day-to-day experience is the same: open the IOTMGR app, tap to start or stop, set a schedule, check status. What actually changes inside the cabinet is the core component that drives the motor — and it grows more capable as the pump grows. For a small pump, a contactor is enough. A medium pump steps up to a soft starter. A large pump uses a VFD.
Find your pump’s power below and read the matching configuration. Each one lists exactly what’s inside and how it works, so you can see precisely what your cabinet would contain.
1 – 7.5 kW
approx. 1 – 10 HP
Core driver: AC contactor

7.5 – 15 kW
approx. 10 – 20 HP
Core driver: soft starter

Above 15 kW
approx. 20 HP and up
Core driver: VFD (variable frequency drive)

That’s the whole logic in one line: as the pump grows, the core driver steps up from contactor to soft starter to VFD, and the protection and supporting parts scale up alongside it. A small greenhouse pump needs very little; a large industrial three-phase pump needs the full set.
The VFD, Explained
A soft starter helps the pump start smoothly and then steps aside. A VFD goes much further: it controls the pump’s speed continuously, the entire time the pump runs.
It works by adjusting the frequency and voltage delivered to the motor. Higher frequency means a faster motor — more flow and pressure; lower frequency means a slower motor — less flow and pressure. The easiest way to picture it: a VFD is like the throttle pedal in a car. Rather than running flat-out and choking the output mechanically, the pump speeds up and eases off smoothly to deliver exactly what’s needed.
For a water pump, that ability brings four real benefits:
1. Flow and pressure on demand. A VFD turns a fixed single-speed pump into one that runs across a whole range of speeds — without swapping the motor or adding gearing. You set the flow and pressure your system needs at any given moment.
2. Constant pressure across irrigation zones. When one pump feeds several zones, opening and closing zones makes the system pressure swing. A VFD senses this and automatically adjusts pump speed to hold a steady discharge pressure, no matter how many zones are open. Paired with our smart valves, this becomes a true closed loop: as the valves switch zones on and off, the VFD keeps pressure constant — every zone gets the right pressure, every time. This pump-and-valve coordination is one of the strongest reasons to run a VFD-based control alongside our smart valves.
3. Real energy savings. Because the pump only works as hard as the moment requires — instead of running full-speed and wasting the surplus — a VFD cuts power use substantially. Industry research indicates variable-speed operation can save roughly 20% to 50% of pump energy versus conventional fixed-speed control. On a pump that runs daily through an irrigation season, that adds up fast.
4. Gentler running, longer life. Like a soft starter, a VFD ramps the motor up and down smoothly — but continuously, not only at startup. That minimizes mechanical stress, removes the harsh current inrush of hard starts, and shields pipes and valves from water hammer. Less stress means fewer repairs and a longer service life.

Do You Actually Need a VFD? Required vs Optional
This is the question nearly every customer arrives at. The answer comes down to pump size, and it splits cleanly into two cases.
So if you have a small pump and you’re weighing a VFD, the question isn’t “will it run without one” (it will). It’s whether the upside — steady pressure across your zones, a lower power bill, longer pump life — is worth it for your operation. For a lot of growers running zoned irrigation, it is.
And here’s what takes the pressure off the decision: VFD sizing is forgiving. You don’t need the pump pinned to the exact kilowatt. Slightly oversizing the VFD is normal, accepted practice. A 3 kW (≈ 4 HP) VFD works perfectly for any pump from 1 kW up to 3 kW; for a pump up to about 3 kW, a 5.5 kW (≈ 7.5 HP) VFD is a comfortable, clean match. So you can lock the configuration now and finalize the exact pump later, without boxing yourself in.
RULE OF THUMB — Above 15 kW: VFD required. Below that: optional, and worth it if you want constant pressure, energy savings, and longer pump life. Either way you can size the VFD a little above the pump — common practice, no downside.
How It Works: Phone to Pump in Three Steps
Before the last two choices, here’s the whole system in one picture. Whatever sits inside the cabinet, the signal path is always the same three steps: your phone sends a command over the wireless network; the cabinet receives it and its core driver — a contactor, soft starter, or VFD depending on pump size — switches the pump’s high-voltage circuit; and the pump runs. The cabinet handles all the electrical protection, surge handling, and motor management in between.
The path is identical at every pump size — only the in-cabinet driver changes. That’s why the app experience feels the same whether you’re running a 2 kW greenhouse pump or a 30 kW field pump.
Two Final Choices: Phase and Connectivity
Beyond power, two smaller decisions round out the configuration. Both are easy.
Single-phase vs three-phase. This follows your power supply. Single-phase 220V is typical for residential and small agricultural pumps; three-phase 380V/415V is used for larger industrial pumps. You don’t have to work it out — your pump’s nameplate states which it is, so just read it off the label.
4G vs LoRaWAN. This is how the cabinet talks to your phone. 4G works anywhere with a mobile signal — the simplest option for a standalone pump or a small site. LoRaWAN needs a gateway on your property, but once it’s in place that gateway can carry hundreds of devices on one network — the better fit when the pump is part of a larger farm system with many smart valves and sensors. If you’re already running our smart valves over LoRaWAN, putting the pump on the same network keeps everything unified.
Putting It All Together
Choosing a remote pump control follows a short, predictable path. Read the rated power off the nameplate. That power sets the configuration: small pumps use a contactor and DTU; medium pumps step up to a soft starter; large pumps use a VFD. Decide whether a VFD makes sense for you — required above 15 kW, optional and often worthwhile below it. Note your phase and your connectivity preference. That’s the whole specification.
A quick worked example. Say you have a 2.2 kW (≈ 3 HP) single-phase pump and want to control it over 4G. You’re in the small configuration — an MCB, AC contactor, DTU, and power supply. No soft starter or VFD is required, though you could add a VFD if constant pressure or energy savings appeal to you. Send a photo of the nameplate with those two preferences and that’s enough to specify the cabinet.
And because each configuration is matched to a power range rather than an exact model, you can plan the controller before the pump is even finalized. The tolerance is wide enough that starting early won’t trip you up.
Frequently Asked Questions
Can I plan my pump controller before I’ve chosen my exact pump?
Yes. Controllers are matched to power ranges, not specific pump models, so knowing the rough size is enough to begin. If you know your pump will land somewhere around 1–3 kW, that’s already enough to configure a small-tier controller. VFD sizing in particular is forgiving — a slightly oversized VFD works fine — so you can settle the configuration and finalize the exact pump later.
Will a 3 kW VFD work for a 1.5 kW pump?
Yes, perfectly. Slightly oversizing a VFD is common, accepted practice and causes no problems. A 3 kW (≈ 4 HP) VFD covers any pump from 1 kW to 3 kW. For a pump up to about 3 kW, a 5.5 kW (≈ 7.5 HP) VFD is also a clean, comfortable match. Going a size up won’t damage anything or cost you performance.
Do I need a soft starter for my pump?
A soft starter becomes the core driver for pumps from 7.5 kW (≈ 10 HP) up to 15 kW. Below that, a contactor and DTU switch the pump fine. The soft starter ramps the motor up gradually rather than slamming it to full power — preventing water hammer, easing electrical surge stress, and extending motor life. Above 15 kW, a VFD takes over this role entirely and adds continuous speed control on top.
What’s the difference between a soft starter and a VFD?
A soft starter only smooths the startup — it eases the motor up, then steps aside while the pump runs at full speed. A VFD controls speed continuously, the whole time the pump runs. That’s why a VFD can do things a soft starter can’t: hold constant pressure across irrigation zones, save energy by matching speed to demand, and protect the system throughout operation rather than only at the start.
What information do you need to quote a pump controller?
Three things, most of them on the nameplate: (1) pump rated power in kW or HP, (2) supply type — single-phase 220V or three-phase 380V, and (3) connectivity — 4G or LoRaWAN. Send a photo of the nameplate plus those preferences and we can specify a complete cabinet.
Next steps:
Ready to spec a pump controller?
→ See the Remote Pump Control product page — send your pump nameplate for a custom configuration.
Building a complete system? Pair the pump with smart valves:
→ Smart Ball Valves · Butterfly Valves · 3-Way Valves
See how pump + valves work as one system:
→ The Complete Guide to Smart Wireless Irrigation Valves
Have a specific pump in mind?
→ Contact our team, or tap the WhatsApp button in the corner of any page to message an engineer directly.
Our valve builds custom remote pump control cabinets for pumps from 1 kW greenhouse units to 100+ kW industrial three-phase motors, deployed across 30+ countries. Every cabinet is configured around your specific pump — send us your nameplate and we’ll specify a complete solution.