Smart Irrigation Accessories

Smart Flow Meters — Measure the Water, Then Stop It at the Number

See how much water each valve has passed, in real time. Set a volume — 1,000 litres to a block — and the valve closes itself when the meter reaches it. Turbine, clamp-on ultrasonic, or inline ultrasonic, sized to match our smart valve.

Real-Time Volume Volume-Based Auto Shutoff 3 Meter Types Clamp-On Option Pairs With Our Smart Valves
Card-type clamp-on ultrasonic flow meter for irrigation water volume measurement and volume-based valve shutoff
Our Flow Meters

Three Flow Meters for Every Pipe

From budget-friendly mechanical metering to non-invasive ultrasonic measurement, choose the right type based on your installation conditions and accuracy requirements.

Mechanical turbine flow meter for agricultural irrigation water measurement, DN32 to DN200

Turbine Flow Meter

Mechanical turbine measurement for cost-effective standard installations. ±3% accuracy, ideal for budget-sensitive agricultural projects.

In-line pipe-type ultrasonic flow meter for high-precision irrigation flow measurement in new installations

Pipe-Type Ultrasonic Flow Meter

In-line ultrasonic measurement for new pipe installations. ±1% accuracy — the highest precision option for critical measurement applications.

What It Does

Two Things a Flow Meter Adds to a Smart Valve

A valve on its own opens and closes on a clock. Add a meter and it works to a number instead.

01

Real-Time Volume Through Every Valve

The meter sits with the valve and reports how much water has passed — live, and totalled by day, week, and season. You can see which block took 40 m³ last week and which one took 12, without walking the field or reading a dial.

Data flows through the valve's own 4G or LoRaWAN link, so a meter needs no separate SIM, gateway, or power supply of its own.

02

Irrigate by Volume, Not by Clock

Set a target in the app — say 1,000 litres for one block — and the valve closes itself the moment the meter reaches it. No timer to calculate, no one sent out to shut it off.

This matters because a timed cycle does not deliver a fixed volume. Run the same valve for thirty minutes at high pump pressure and again when the pressure has dropped, and the two blocks get different amounts of water. A volume target removes that variable: every block gets what you asked for, whatever the line is doing that day.

Decision Helper

Compare Three Flow Meter Types

All three options output via RS485 and integrate with the IOTMGR app. The differences come down to installation method, accuracy, and best-fit scenarios.

TurbineCard-Type Ultrasonic Most PopularPipe-Type Ultrasonic
Measurement MethodMechanical turbineInline ultrasonic
Installation DifficultyModerate — requires fittingRequires pipe cutting
Typical Accuracy±3%±1%
Pipe Size RangeDN32 – DN200DN50 – DN300
Best ForBudget-sensitive standard installsNew installations needing top precision
CommunicationRS485RS485
Card-Type in Action

Clamp-On Installation, Real Pipelines

The Card-Type Ultrasonic Flow Meter mounts directly to existing pipes — no shutdown, no cutting, no welding. Below: real installations on agricultural smart valve assemblies.

Card-type ultrasonic flow meter clamped onto irrigation pipeline paired with smart valve in real installation

Card-Type Ultrasonic Flow Meter clamped onto an irrigation pipeline paired with a smart valve — installation completed in under 15 minutes without interrupting water service.

Real-world field installation of card-type flow meter alongside solar-powered smart valve on agricultural irrigation main

Field installation showing the Card-Type Flow Meter alongside our solar-powered smart valve — flow data travels over the valve's own wireless link, so the meter needs no SIM or power supply of its own.

Pair with Smart Valves

Flow Meters Work Best Paired with Smart Valves

A flow meter on its own measures water. A smart valve on its own opens and closes on a clock. Put them together and the valve can work to a volume instead — 1,000 litres to a block, then it shuts. Pick the valve that matches your pipe below.

Frequently Asked

Common Questions About Flow Meters

Answers to what buyers ask most. For project-specific recommendations, contact our sales team.

What can a flow meter actually do for me?

Two things. First, it shows how much water has passed through each valve — live, and totalled by day, week, and season, so you can see which block took 40 m³ last week and which took 12.

Second, it lets the valve work to a volume instead of a clock. Set a target of 1,000 litres for a block and the valve closes itself the moment the meter reaches it.

How does volume-based irrigation work?

You set a volume for the valve in the app — 1,000 litres, 5 m³, whatever the block needs. The valve opens, the meter counts, and when the number is reached the valve closes on its own. No timer to calculate and nobody sent out to shut it off.

You can still run the same valve on a schedule for other cycles. Volume targets and time-based schedules both work.

Why not just irrigate on a timer?

Because the same length of time does not deliver the same amount of water. Run a valve for thirty minutes when the pump is at full pressure, then again when pressure has dropped because three other zones are open, and the two blocks get very different volumes.

A volume target removes that variable. Every block gets what you asked for, whatever the line is doing that day. This matters most where a crop needs a measured dose, or where water is allocated and metered.

Which flow meter type should I choose?

Card-Type Ultrasonic is what most customers pick. It clamps onto the outside of the pipe with no cutting, at ±2% accuracy.

Turbine is the lower-cost option for standard installs, at ±3%.

Pipe-Type Ultrasonic mounts inline at ±1% — for new pipework where precision matters most.

Size follows your valve, so tell us the valve and we will match the meter.

Can I fit one without cutting my pipe?

Yes — the Card-Type Ultrasonic is a clamp-on design. It goes on the outside of the existing pipe, with no cutting, no welding, and no need to shut the line down.

Typical fitting time is 10 to 15 minutes per unit, which is why it is the usual choice for adding metering to a network already in the ground.

Does the meter need its own SIM card or power supply?

No. The meter connects to the smart valve it sits with, and the data travels over that valve's existing 4G or LoRaWAN link.

One less SIM to pay for, one less thing to power, and one less device to commission on site.

Can I pull the flow data into my own system?

Yes. Flow readings are available over API alongside valve status, so you can bring them into your own platform, ERP, or farm management software.

Talk to our sales engineer about what your system needs.

Get a Quote for Your Smart Valve Project

Share your pipe sizes, farm size, and deployment needs — our engineering team will respond with model recommendations and a project-specific quote within 24 hours.

Want to see how this fits into a complete smart irrigation system?

Read our Complete Guide to Smart Irrigation Valves — covering how the system works, real ROI from 30+ country deployments, and how to configure it for your farm.